Original contribution
Age-related changes in carotid artery wall properties in men

https://doi.org/10.1016/0301-5629(86)90218-8Get rights and content

Abstract

Changes in distensibility and cross-sectional compliance of the common carotid artery with age were studied in 80 presumed healthy volunteers, varying in age between 20 and 69 y. The distensibility was assessed from the relative increase in arterial diameter during systole normalized with respect to the arterial pulse pressure. The cross-sectional compliance was obtained by multiplying the distensibility by the arterial diameter. The relative diameter changes of the common carotid artery during the cardiac cycle were recorded on-line with a high resolution multigate pulsed Doppler system. The arterial diameter was assessed from the width of the velocity profiles which can also be recorded on-line with this system. Arterial pulse pressure was determined from brachial artery cuff blood pressure measurements. Both distensibility and cross-sectional compliance of the common carotid artery decreased linearly with age, starting in the third age decade. The reduction in the latter parameter was less pronounced, probably as a consequence of an increase in arterial diameter with age.

References (21)

  • A.P.G. Hoeks et al.

    Transcutaneous detection of relative changes in artery diameter

    Ultrasound in Med. & Biol.

    (1985)
  • R.S. Reneman et al.

    Local Doppler audio spectra in normal and stenosed carotid arteries in man

    Ultrasound in Med. & Biol.

    (1979)
  • B.T. Altura et al.

    Pentobarbital and contraction of vascular smooth muscle

    Am. J. Physiol.

    (1975)
  • J.O. Arndt et al.

    The diameter of the intact carotid artery in man and its change with pulse pressure

    Pfluegers Arch.

    (1968)
  • D.H. Bergel

    Cardiovascular Fluid Dynamics

    (1972)
  • W.J. Dixon et al.

    Biomedical Computer Program P-Series

    (1981)
  • B.S. Gow et al.

    The elasticity of canine and human coronary arteries with reference to postmortem changes

    Circ. Res.

    (1979)
  • A.P.G. Hoeks et al.

    A multigate pulsed Doppler system with serial data processing

    IEEE Trans. Sonics Ultrasonics SU-28

    (1981)
  • A.P.G. Hoeks et al.

    A novel frequency estimator for sampled Doppler signals

    IEEE Trans. Biomed. Eng. BME-31

    (1984)
  • K.G. Joreskog et al.
There are more references available in the full text version of this article.

Cited by (235)

View all citing articles on Scopus
View full text