Table 3

Sentivity and specificity of statistically significant variables

TestsFormulaConcentric Peak Torque (CPT) Results (IC95%)Concentric Power (CJ) Results (IC95%)
Sensitivity Embedded Image 5.47%3.10% to 8.87%4.97%2.87% to 7.94%
Specificity Embedded Image 98.70%96.71% to 99.65%98.85%96.67% to 99.76%
Positive Likelihood Ratio Embedded Image 4.221.42 to 12.554.311.27 to 14.62
Disease prevalence Embedded Image 0.960.93 to 0.990.960.93 to 0.99
Positive Predictive Value Embedded Image 47.08%42.96% to 51.23%55.33%51.18% to 59.42%
Negative Predictive Value Embedded Image 78.95%55.75% to 91.78%84.21%61.10% to 94.77%
Accuracy Embedded Image 54.00%53.22% to 54.77%45.65%44.95% to 46.35%
  • a (True Positive), b (False Positive), c (False Negative), d (True Negative).

  • IC 95%, 95% Interval of Confidence.